The most critical identified issues were specification inaccuracies rather than programming errors. Don Eyles, author of lunar landing guidance software, documented several instances. For example, the rendezvous radar interface specification indicated two 800 Hz power supplies would be frequency-synchronized but omitted phase alignment requirements. Resulting phase drift created apparent antenna oscillation, generating approximately 6,400 false interrupts per second per angle and consuming about 13% of computational capacity during Apollo 11's descent. This constituted the fundamental origin of the 1202 alarms.